AccuSoft Partners

Epson GT-2500

Manufacturer: Epson
Model: GT-2500
Tested: July 2006
 

Certification Details

 

The AccuSoft scanner certification testing has two distinctive parts, capability and benchmarking. Based on the test results, the Epson GT-2500 is certified with ImageGear Professional as a supported scanner.

TWAIN Capability Test

The TWAIN 1.9 standard is the basis of the functions tested.  The tests verify the TWAIN functions which the scanner claims to support as well as the functions which are actually supported when using our imaging toolkit, ImageGear.

The capability testing showed the scanner is compatible with ImageGear via a TWAIN interface.  A total of 35 claimed functions pass and were available to ImageGear. See the test result details.

Benchmark Test

A time and page count measurement is taken for scanned image throughput. The test is performed by scanning a range of documents with differing page count, bit depth, and resolution.

The benchmark testing showed a capture rate from 9 pages-per- minute at 100 dots-per-inch and 24 bit-per-pixel when scanning multiple pages and 8 pages-per-minute at 100 dots-per-inch and 1 bit-per-pixel when scanning a single page. See the test result details.

Below are the test result details:

TWAIN Capability Test Results

HW = Supported by scanner hardware
SW = Supported by ImageGear software
 

TWAIN capability GET GET
Current
GET
Default
SET RESET
HW SW HW SW HW SW HW SW HW SW
CAP_DEVICEONLINE - - -
CAP_DUPLEX - - - -- -
CAP_FEEDERENABLED -- -
CAP_FEEDERLOADED -- -
CAP_FEEDERORDER -- - -- -
CAP_SUPPORTEDCAPS -- -
CAP_UICONTROLLABLE - - - - - -
CAP_XFERCOUNT -
ICAP_BITDEPTH - - -
ICAP_BITORDER - - -
ICAP_BRIGHTNESS - - - - - -
ICAP_COMPRESSION - - -
ICAP_CONTRAST - - - - - -
ICAP_FILTER - - - - - - - - -
ICAP_FRAMES - - - - - -
ICAP_GAMMA - - - - - -
ICAP_HALFTONES - - - - - -
ICAP_IMAGEFILEFORMAT - - - - - -
ICAP_LIGHTPATH - - - - - -
ICAP_LIGHTSOURCE - - - - - -
ICAP_ORIENTATION - - - - - -
ICAP_PHYSICALHEIGHT - - -
ICAP_PHYSICALWIDTH - - -
ICAP_PIXELFLAVOR -
ICAP_PIXELTYPE -
ICAP_PLANARCHUNKY - - -
ICAP_THRESHOLD - - - - - -
ICAP_UNITS -
ICAP_XFERMECH - - -
ICAP_XNATIVERESOLUTION - - - - - -
ICAP_XRESOLUTION -
ICAP_XSCALING - - - - - -
ICAP_YNATIVERESOLUTION - - - - - -
ICAP_YRESOLUTION -
ICAP_YSCALING - - - - - -
TWAIN capability HW SW HW SW HW SW HW SW HW SW
GET GET
Current
GET
Default
SET RESET
HW = Supported by scanner hardware
SW = Supported by ImageGear software

Benchmark Test

Resolution
(dpi)
Bit
Depth
Duplex
Scan
Time
(ms)
8.5" x 14"
Pages
Speed
(ppm)
100 1 no 8000 1 8
100 1 yes 35000 5 9
100 8 no 10000 1 6
100 8 yes 34000 5 9
100 24 no 10000 1 6
100 24 yes 34000 5 9
300 1 no 24000 1 2
300 1 yes 118000 5 3
300 8 no 24000 1 2
300 8 yes 118000 5 3
300 24 no 23000 1 3
300 24 yes 119000 5 3
600 1 no 78000 1 1
600 1 yes 118000 5 3
600 8 no 78000 1 1
600 8 yes 119000 5 3
600 24 no 76000 1 1
600 24 yes 120000 5 2